Sel 487e Relay Manual
SEL-487E-3, -4 Transformer Differential Relay Three-Phase Transformer Protection, Automation, and Control System Major Features and Benefits The SEL-487E Transformer Differential Relay provides three-phase differential protection for transformer applications with as many as five three-phase restraint current inputs. Use the three independent restricted earth fault (REF) elements for sensitive ground-fault detection in grounded wye-transformer applications. Detect turn-to-turn winding faults for as little as two percent of the total transformer winding with the negative-sequence differential element. Apply the two three-phase voltage inputs for over- and undervoltage, frequency, and volts/hertz protection. Make any overcurrent element directional using voltage polarized directional elements as torque control inputs to the overcurrent elements.
Date Code 20070219 Instruction Manual SEL-2506 Module SEL-2506 Remote I/O Module Instruction Manual Features, Benefits, and Applications The SEL-2506 is a two rack unit remote I/O module that has ei ght contact inputs and eight co ntact outputs. Jan 29, 2018 - File: sel-387e sel 487e price sel 487b relay instruction manual sel-487e pmu sel-487e data sheet sel 411l relay manual sel 487b sel 487v The.
Monitor and protect critical substation assets with comprehensive breaker wear and transformer thermal and through-fault monitoring. Nsimsun font. Perform bay control functions for as many as five breakers and 20 disconnect switches using the built-in system mimic diagrams.
Schweitzer Engineering Laboratories, Inc. High-Speed Differential Protection.
A two-stage slope adapts automatically to external fault conditions, providing fast, sensitive, dependable, and secure differential protection, even for CT saturation and heavily distorted waveforms. Multiple Synchrophasor Data Channels. System-wide monitoring is available through as many as 24 synchrophasor data channels. Record and store up to 120 seconds of IEEE C37.118 binary synchrophasor data.
Restricted Earth Fault Protection. Three independent REF elements provide sensitive protection for faults close to the winding neutral in grounded wye-connected. ► Time-Domain Link (TiDL) Technology. The relay supports remote data acquisition through use of the SEL-2240 Axion®. The Axion provides remote analog and digital data over an IEC 61158 EtherCAT® TiDL network.
This technology provides very low and deterministic latency over a fiber point-to-point architecture. The SEL-487E-3, -4 relay can receive fiber links from as many as eight Axion remote data acquisition nodes. Functional Overview 1 Copper or Fiber Optic * Optional Feature Figure 1 Functional Diagram Schweitzer Engineering Laboratories, Inc. High Voltage Transformer Differential Zone Tertiary Voltage Two-Winding Transformer Application Use the negative-sequence differential element for sensitive detection of interturn faults within the transformer winding. Phase, negative-, and zero-sequence overcurrent elements provide backup protection. Use breaker failure protection with subsidence detection to detect breaker failure and minimize system coordination times. When voltage inputs are provided to the SEL-487E, voltage-based protection elements and frequency tracking are made available.